1. S49-A series vibration sieve inlet and outlet connection and whatis the best way to place the installation of screening machines?
A: (bag) flexible connection;
2. What is motor power of complete WS seriesairflow sieve various parts? How to place the sieve machine?
A: The machine body power: 4.5 5.0 5.5kw
Fan power: 4.0 4.5 5.5kw
Cyclone collector: 0.75kw
Because the airflow sieve machine does not vibrate itself, but also through the repeated test machine, to determine the best location of the three parts to ensure smooth air duct, get the best screening results; if the screening material has changed, still need to change the three positions, so the air flow Sieve without fixed, it can be placed on the ground level.
3. Commonly used explosion-proof motor protection level;
dIIBT4 - IP44
dIIBT4 - IP55
Common explosion-proof motor for air sieve, vibrating sieve and circular vibrating screen using ordinary motor equipment.
Common motor protection level is IP54
Gas flameproof flag YB
Dust flameproof flag YEB
4.The difference between common motor and vibration motor:
Common motor: National uniform standard, easy maintenance, low maintenance costs, but electricity, high base.
Vibration motor: need specially-assigned person to repair; energy saving, low base, easy to assemble and assemble;
Both use the same effect, the cost is quite, arbitrary choice according to the use of .