Preparation of vibrating sieve before installation
- Check the motor signs are consistent with the requirements;
- With 500 V megohmmeter insulation resistance measurement, the value of the stator winding should be dried, drying temperature can not exceed 120 ℃;
- Check the motor fasteners, beware of loose;
- Check the motor surface for damage, deformation;
- Check whether the flexible rotation, if abnormal, it should be excluded;
- Check the power, whether the lack of phase, and no-load operation for 5 minutes.
Rotary vibrating sieve installation and adjustment
- The equipment motor should be fastened on the mounting surface, the mounting surface must be smooth, smooth;
- The motor can be installed horizontally
- The motor lead with four-core rubber cable YZ-500V, then the power cord lead wire is not allowed to havebend, and fixed with vibration body;
- The motor should be reliably grounded, there are grounding devices in the motor, lead the end of a sign, you can also use the firm foot bolts grounding;
- Exciting force adjustment.